  • 2(1750233060228).jpg

Disc-type suspended tempered glass insulator

Manufacturer-supplied / Professionally manufactured / Consistently high quality

WhatsApp:

Keywords:

Glass insulator

glass insulator

glass insulator

Share to

  • Product Description
  • Glass insulator

    U70

    Universal model U70B/140 U70B/146 U70B/127
    Hebei Xinwang Electric Power Equipment Co., Ltd. model LXY₃-70 LXY₁-70 LXY₂-70
    Nominal diameter D (mm) 255 255 255
    Structural height H (mm) 140 146 127
    Nominal creepage distance L (mm) 320 320 320
    Connection type (mm) 16 16 16
    Mechanical failure load (kN) 70 70 70
    Individual tensile load test (kN) 35 35 35
    Power-frequency wet withstand voltage (kV) 40 40 40
    Lightning Impulse Withstand Voltage (kV) 100 100 100
    Impact Breakdown Voltage (PU) 2.8 2.8 2.8
    Power-frequency breakdown voltage (kV) 130 130 130
    Radio interference voltage (μV) (10 kV, 1 MHz) 50 50 50
    Visible corona voltage (kV) 18/22 18/22 18/22
    Power-frequency arc test 0.125/20KA 0.125/20KA 0.125/20KA
    Net weight of a single insulator (kg) 3.6 3.6 3.5

    U100,120

    Universal model U100B/146 U100B/127 U120B/146 U120B/127
    Hebei Xinwang Electric Power Equipment Co., Ltd. model LXY-100 LXY₂-100 LXY₃-120 LXY₂-120
    Nominal diameter D (mm) 255 255 255 255
    Structural height H (mm) 146 127 146 127
    Nominal creepage distance L (mm) 320 320 320 320
    Connection type (mm) 16 16 16 16
    Mechanical failure load (kN) 70 70 70 70
    Individual tensile load test (kN) 35 35 35 35
    Power-frequency wet withstand voltage (kV) 40 40 40 40
    Lightning Impulse Withstand Voltage (kV) 100 100 100 100
    Impact Breakdown Voltage (PU) 2.8 2.8 2.8 2.8
    Power-frequency breakdown voltage (kV) 130 130 130 130
    Radio interference voltage (μV) (10 kV, 1 MHz) 50 50 50 50
    Visible corona voltage (kV) 18/22 18/22 18/22 18/22
    Power-frequency arc test 0.125/20KA 0.125/20KA 0.125/20KA 0.125/20KA
    Net weight of a single insulator (kg) 4 4 4 4

    U160.210

    Universal model U160B/170 U160B/155 U160B/146 U210B/170 U210B/170
    Hebei Xinwang Electric Power Equipment Co., Ltd. model LXY-160 LXY₅-160 LXY₄-160 LXY₅-210 LXY₇-210
    Nominal diameter D (mm) 280 280 280 280 280
    Structural height H (mm) 170 155 146 170 170
    Nominal creepage distance L (mm) 320 400 400 400 450
    Connection type (mm) 16 20 20 20 20
    Mechanical failure load (kN) 70 160 160 160 160
    Individual tensile load test (kN) 35 80 80 80 80
    Power-frequency wet withstand voltage (kV) 40 45 45 45 45
    Lightning Impulse Withstand Voltage (kV) 100 110 110 110 110
    Impact Breakdown Voltage (PU) 2.8 2.8 2.8 2.8 2.8
    Power-frequency breakdown voltage (kV) 130 *130 *130 *130 *130
    Radio interference voltage (μV) (10 kV, 1 MHz) 50 50 50 50 50
    Visible corona voltage (kV) 18/22 18/22 18/22 18/22 18/22
    Power-frequency arc test 0.125/20KA 0.12S/20KA 0.12S/20KA 0.12S/20KA 0.12S/20KA
    Net weight of a single insulator (kg) 6.7 6.6 6.5 7.2 7.3

    U240,300,420

    Parameter item U240B /170 U240B /170 U240B /170 U300B /195 U420B /200
    Universal model U240B /170 U240B /170 U240B /170 U300B /195 U420B /200
    Hebei Xinwang Electric Power Equipment Co., Ltd. model LXY-240 LXY₁-240 LXY₂-240 LXY₃-300 LXY-420-400
    Nominal diameter D (mm) 280 280 280 320 280
    Structural height H (mm) 170 170 170 195 170
    Nominal creepage distance L (mm) 400 400 400 485 320
    Connection type (mm) 20 20 20 20 20
    Mechanical failure load (kN) 160 160 160 160 160
    Individual tensile load test (kN) 80 80 80 80 80
    Power-frequency wet withstand voltage (kV) 45 45 45 45 45
    Lightning Impulse Withstand Voltage (kV) 110 110 110 110 110
    Impact Breakdown Voltage (PU) 2.8 2.8 2.8 2.8 2.8
    Power-frequency breakdown voltage (kV) *130 *130 *130 *130 *130
    Radio interference voltage (μV) (10 kV, 1 MHz) 50 50 50 50 50
    Visible corona voltage (kV) 18/22 18/22 18/22 18/22 18/22
    Power-frequency arc test 0.12S/20KA 0.12S/20KA 0.12S/20KA 0.12S/20KA 0.12S/20KA
    Net weight of a single insulator (kg) 7.2 7.5 7.6 10.6 16

    Stain-resistant insulator

    Generic code U70BP/146 U70BP/146 U70BP/146 U100BP/146 U100BP/146 U100BP/146 U120BP/146
    Hebei Xinwang model LXHY₄-70 LXHY₅-70 LXHY₆-70 LXHY₃-100 LXHY₄-100 LXHY₆-100 LXHY₃-120
    Nominal diameter D (mm) 255 255 255 255 280 320 260
    Structural height H (mm) 146 146 146 146 146 146 146
    Nominal creepage distance (mm) 400 400 400 400 450 550 400
    Connection Type (mm) 16 16 16 16 16 16 16
    Mechanical failure load (kN) 70 70 70 70 100 100 120
    Individual tensile load test (kN) 35 35 35 35 50 50 60
    Power-frequency wet flashover voltage (kV) 45 45 45 45 50 55 45
    Lightning Impulse Withstand Voltage (kV) 110 110 110 110 125 140 110
    Impact Breakdown Voltage (PU) 2.8 2.8 2.8 2.8 2.8 2.8 2.8
    Power-frequency breakdown voltage (kV) 130 130 130 130 130 130 130
    Radio interference voltage (μV, 10 kV/1 MHz) 50 50 50 50 50 50 50
    Visible corona voltage (kV) 18/22 18/22 18/22 18/22 18/22 18/22 18/22
    Power-frequency arc test 0.125/20KA 0.125/20KA 0.125/20KA 0.12S/22.KA 0.12S/22.KA 0.12S/22.KA 0.12S/22.KA
    Net weight per piece (kg) 4.6 5.8 9.2 5.4 5.8 9.2 5.4

     

    Generic code U120BP/146 U120BP/146 U160BP/155 U160BP/155 U160BP/155 U160BP/170 U210BP/170
    Hebei Xinwang model LXHY₄-120 LXHY₆-120 LXHY₃-160 LXHY₄-160 LXHY₆-160 LXHY₅-160 LXHY₃-210
    Nominal diameter D (mm) 280 320 280 280 320 320 320
    Structural height H (mm) 146 146 155 170 155 170 170
    Nominal creepage distance (mm) 450 550 450 450 550 550 550
    Connection Type (mm) 16 16 20 20 20 20 20
    Mechanical failure load (kN) 120 120 160 160 160 160 210
    Individual tensile load test (kN) 60 60 80 80 80 80 105
    Power-frequency wet flashover voltage (kV) 45 55 50 50 55 55 55
    Lightning Impulse Withstand Voltage (kV) 110 140 125 125 140 140 140
    Impact Breakdown Voltage (PU) 2.8 2.8 2.8 2.8 2.8 2.8 2.8
    Power-frequency breakdown voltage (kV) 130 130 *130 *130 *130 *130 *130
    Radio interference voltage (μV, 10 kV/1 MHz) 50 50 50 50 50 50 50
    Visible corona voltage (kV) 18/22 18/22 18/22 18/22 18/22 18/22 18/22
    Power-frequency arc test 0.12S/22.KA 0.12S/22.KA 0.12S/22.KA 0.12S/22.KA 0.12S/20KA 0.12S/20KA 0.125/20KA
    Net weight per piece (kg) 5.8 9.2 7.1 7.2 9.5 9.6 10.2

     

    Generic code U210BP/155 U240BP/170 U240BP/170 U300BP/195 U300BP/195 U420BP/195
    Hebei Xinwang model LXHY₄-210 LXHY₃-240 LXHY₄-240 LXHY-300 LXHY₂-300 LXHY₅-300
    Nominal diameter D (mm) 320 320 320 300 340 380
    Structural height H (mm) 155 170 170 195 195 195
    Nominal creepage distance (mm) 550 550 550 600 550 635
    Connection Type (mm) 20 20 24 24 24 24
    Mechanical failure load (kN) 210 240 240 300 300 300
    Individual tensile load test (kN) 105 120 120 150 150 150
    Power-frequency wet flashover voltage (kV) 55 55 55 60 55 60
    Lightning Impulse Withstand Voltage (kV) 140 140 140 155 140 155
    Impact Breakdown Voltage (PU) 2.8 2.8 2.8 2.8 2.8 2.8
    Power-frequency breakdown voltage (kV) *130 *130 *130 *130 *130 *130
    Radio interference voltage (μV, 10 kV/1 MHz) 50 50 50 50 50 50
    Visible corona voltage (kV) 18/22 18/22 18/22 18/22 18/22 18/22
    Power-frequency arc test 0.12S/20KA 0.12S/20KA 0.12S/20KA 0.12S/20KA 0.12S/20KA 0.12S/20KA
    Net weight per piece (kg) 11.1 10.2 10.4 15 12.5 14.5

    Production Capacity

     

Our advantages

Experienced

More than 15 years of production experience, worry-free after-sales service.

Full category production strength

Covering a full range of equipment for 10-500 kV power transmission and distribution, thousands of products in 10 categories are adapted to diverse scenarios, realizing one-stop supply of insulators, cables, hardware, etc.

Fast delivery

Sufficient inventory, fast and safe delivery.

Factory real view

Factory Environment

Factory Environment

Office Building

Office Building

Payment and distribution

T/T L/C

★ If your order is not very big, we can send it to you by TNT, DHL, UPS or EMS etc.

★ If your order is large, we will suggest you use air or sea freight through your designated freight forwarder. We also have long-term cooperative agents.

7-10 working days

7-10 working days

7-10 working days

7-10 working days

Payment and Distribution

7-10 working days

7-10 working days

7-10 working days

7-10 working days

7-10 working days

Payment and distribution

Common Problems

What is the product's after-sales warranty period, and how are quality issues handled?

The product's free warranty period is 12 months. During the warranty period, if quality problems arise due to product design, manufacturing, or material defects, we are responsible for free repair or replacement. You can call our after-sales service at 0317 - 3667793, and we will respond within 12 hours of receiving feedback and arrange for professionals to resolve the issue. Beyond the warranty period, we also provide paid lifetime maintenance services, charging only for the cost of spare parts.

What logistics method is generally used for product delivery, and how long does it take to arrive?

We cooperate with many well-known logistics companies to comprehensively select suitable logistics according to your delivery address and cargo weight and volume. Domestically, it generally takes 3 - 7 working days to arrive, and remote areas may be slightly delayed; international orders are determined according to the specific destination and transportation method, usually in 15 - 30 days or so, we will follow up the logistics information and give feedback to you in time.

I would like to customize electrical equipment with special specifications. Can your company undertake this?

Yes, we have strong technical strength and a professional R&D team. You only need to inform us of your special specifications, and we will evaluate the feasibility and customize a production plan for you to ensure that your needs are met.

What is the process for ordering products from your company?

First, you select your favorite products on the website and submit an online inquiry or call our customer service at 0317 - 3667793 for consultation. After receiving the information, we will communicate with you about product details, prices, and delivery times. After both parties confirm that there are no errors, we will sign a contract. You will pay the amount as agreed in the contract, and we will arrange production and delivery.

How to view the parameters and model of a specific electrical equipment?

You can visit the product details page of the website. Each product has a detailed parameter introduction, including technical specifications, applicable scenarios and other information. If you still have questions, you can always contact our customer service staff. The contact information is at the bottom of the website homepage.

What electrical equipment products does your company mainly produce?

Our company specializes in producing products for 10 - 500 kV transmission, substation, and distribution projects, covering ceramic insulators, composite insulators, tempered glass insulators, matching hardware, zinc oxide arresters, drop-out fuses, disconnect switches, overhead insulated wires, steel-cored aluminum stranded wires, power cables, iron fittings, and other 10 major categories with thousands of products.

Get more product information

* Filling in your phone and E-mail information will help us contact you in time and solve the problems you raised as soon as possible.

Submit Message